SmartGen | SmartGen New BMS Module HBMU200 Launched

HBMU200 (BMS Slave Control Module) is applied to the energy storage BMS system to realize the collection of single battery voltage and battery temperature, and upload information to HBCU100 (BMS master control module) through the CAN bus. It is a subsystem of the whole intelligent micro-grid control system.

Performance and Characteristics

1. With status indicator;
2.The mature AFE chip in the industry is used to realize the voltage detection of single battery, which supports the voltage detection of 5-16 strings of single batteries;
3.With single battery disconnection detection;
4.Supports up to 18 channels of temperature detection, and the temperature sensor type is NTC 10K;
5.One relay output is provided for controlling fans and other equipment;
6.One non-isolated CAN interface is provided for communication with the master control module HBCU100. The module firmware program can also be upgraded via the CAN interface;
7.The 120Ω terminal matching resistance on the CAN bus is connected through the dial switch;
8.Select the CAN ID number of the module through the dial switch, and the setting range is 1-63;
9.With passive balance function, max passive balance current is 100mA;
10.With the harness protection function, when the HBMU200 is used externally, the enclosure is equipped with a harness protection cover which can be selected to avoid damage to the harness;
11.Modular design, screw installation, flame-retardant ABS/PC shell, compact structure with easy installation.

BMS Master Control Module HBCU100

1.Can collect total battery voltage and current (Hall current sensor), calculate the SOC and SOH data;
2.Can collect positive and negative battery insulation resistance to ground;
3.Receive the voltage and temperature of the single cell of HBMU200 module via the non-isolated CAN interface and calculate the data of max. and min. voltage/temperature, etc.;
4.Tertiary fault alarm protection can protect the over/under voltage, high/low temperature, charge/discharge overcurrent, low insulation resistance value, abnormal communication, etc., current drop or high voltage power-off actions can be set;
5.With 3 isolated RS485 communication interfaces, 1 ETHERNET interface, and bluetooth function;
6.With 7 Aux. relay output ports.

HMU8-BMS Display Module


1.Adopt 8-inch LCD with 800*600 resolution, capacitive touch screen and optional Chinese/English operation;
2.Display battery total voltage, current, SOC and other data;
3.With event log, alarm information display function;
4.Commissioning of single HBMU200 and upgrading of the whole energy storage system can be realized via CAN interface;
5.Modular design and pluggable terminal.

BMS Three-level Architecture Application Diagram

Energy Storage High-voltage Control Box

The energy storage high-voltage control box collects the cell voltage and temperature data of all battery modules through the internal CAN interface to protect the battery modules. Due to the function of communication with PCS, and together with the built-in dual switch (circuit breaker + main circuit relay), it can realize the charge and discharge management of the whole battery system, which is safe and reliable.

HBMU200 Installation Dimension

www.smartgen.cn

发表评论

电子邮件地址不会被公开。 必填项已用*标注